DIS package

The DIS package specifies the grid used for the groundwater model. The grid specification must start with the bottom layer. Afterwards confined/unconfined layer can be added. The maximum number of layers is 999.

The operation for the specification of the bottom layer is

res = mf::createBottomLayer(bottomElevation, topElevation);

where

bottomElevation
is the name of a spatial, scalar PCRaster map containing the bottom elevation values of the layer. The map must not contain missing values;
topElevation
is the name of a spatial, scalar PCRaster map containing the top of layer elevation values. The map must not contain missing values.

The operation to add a layer is

res = mf::addLayer(elevation);

where

elevation
is the name of a spatial, scalar PCRaster map containing the top of layer elevation values. The map must not contain missing values.

The operation to add a confined layer is

res = mf::addConfinedLayer(elevation);

where

elevation
is the name of a spatial, scalar PCRaster map containing the top of layer elevation values. The map must not contain missing values.
_images/layerdesc.png

Layer numbering in Modflow and the PCRasterModflow extension

The figure shows two grid specifications. The left side of the figure represents a four layer system that is specified in a PCRcalc script as follows:

res = mf::createBottomLayer(bottom.map, l4top.map);
res = mf::addLayer(l3top.map);
res = mf::addLayer(l2top.map);
res = mf::addLayer(l1top.map);

The right side of the figure shows a three layer system with a confining bed below layer 2:

res = mf::createBottomLayer(bottom.map, l4top.map);
res = mf::addConfinedLayer(l3top.map);
res = mf::addLayer(l2top.map);
res = mf::addLayer(l1top.map);

The PCRasterModflow extension uses an opposite layer numbering to the Modflow convention. Furthermore quasi-3D confining beds obtain a layer number. Layer numbering always starts with layer number 1 for the bottom layer and increases for each added confined or unconfined layer.

Except for setting the conductivity values all commands operate on layers which are not specified as confining beds. Attempts to set or retrieve values from confining beds will result in an error.

Optional operation

The options for the DIS package can be specified with

res = mf::setDISParameter(ITMUNI,LENUNI,PERLEN,NSTP,TSMULT,SSTR);

where

ITMUNI
indicates the time unit (0: undefined, 1: seconds, 2: minutes, 3: hours, 4: days, 5: years);
LENUNI
indicates the length unit (0: undefined, 1: feet, 2: meters, 3: centimeters);
PERLEN
is the duration of a stress period;
NSTP
is the number of iterations;
TSMULT
is the multiplier for the length of the successive iterations;
SSTR
0 - transient, 1 - steady state. If the simulation is set to transient, primary and secondary storage coeffiecents must be set in the BCF package.

All input values are non spatial values. If this operation is not used the simulation will be set to the default values of (undefined, undefined, 1.0, 1, 1.0, 1).